To find reactive power, the rms voltage and current values are multiplied by the sine of the phase angle, Φ as shown.

What is the relation between reactive power and power factor?

Reactive power (kVAr) is the vector difference between real power (kW), and the total power consumed, which is called apparent power and is measured in kVA. Power factor is a ratio of the real power that is used to do work and the apparent power that is supplied to the circuit.

How do you calculate reactive power from active power and power factor?

This formula is applicable for sinusoidal voltage and current. This is why the Power Factor is then designated as “Displacement Power Factor”….Definition of reactive power

  1. Apparent power: S = V x I (kVA)
  2. Active power: P = V x Ia (kW)
  3. Reactive power: Q = V x Ir (kvar)

What is reactive power formula?

Apparent power: S = V x I (kVA) Active power: P = V x Ia (kW) Reactive power: Q = V x Ir (kvar)

READ ALSO:   How long does Lambton College take for offer letter?

What do you mean by reactive power?

Reactive power is the part of complex power that corresponds to storage and retrieval of energy rather than consumption. On an AC power system, there are two kinds of power – real power that actually does work, and reactive power that enables transformers to transform, generators to generate, and motors to rotate.

What is the effect of reactive power on power factor?

Reactive power is required for the magnetization of an electric motor but does not perform any work. Reactive power required by inductive loads increases the amounts of apparent power – and the required supply to the grid from the power supplier to the distribution system. Increased reactive and apparent power will decrease the power factor – PF.

What is the effect of inductive load on power factor?

Reactive power required by inductive loads increases the amounts of apparent power – and the required supply to the grid from the power supplier to the distribution system. Increased reactive and apparent power will decrease the power factor – PF.

READ ALSO:   Which country introduced total football?

What is the power factor of a purely resistive load?

With a purely resistive load the current and voltage changes polarity in step and the power factor will be 1. Electrical energy flows in a single direction across the network in each cycle. Inductive loads – transformers, motors and wound coils – consumes reactive power with current waveform lagging the voltage.

How to generate VARs from leading power factor loads?

For leading power factor loads it is necessary to add in some means of absorbing reactive power such as series inductance. Alternatively, an option used on some transmission lines is the use of unloaded synchronous motors at the load end of the line: When over-excited the synchronous motor will operate at leading power factor and generate VARs