What is the nominal cover of column?

What is the nominal cover of column?

The nominal cover is the distance between the exposed concrete surface to nearest reinforcement bar ( it may be any bar main bar, longitudinal bar and even links or stirrups). The nominal cover should not be less than the diameter of the bar.

What is the minimum cover for columns?

4.6

Member Minimum Cover
Slab 20 mm
Beam 20 mm
Column 40 mm for d > 12 mm 25 mm for d < 12 mm
Footing 50 mm

What is the normal size of a column?

Standard size of an RCC column should not be less than 9”x 9” (225mm x 225mm) with 4 bars of 12mm Fe500 Steel with m20 grade of concrete and stirrups of T8@6″C/C. I will recommended 9″ × 12″ (230mm × 300mm) standard size of RCC column for ground floor residential building.

READ ALSO:   Does the vagina have erectile tissue?

Why nominal cover is provided?

function and importance of nominal cover of concrete are following:- 1) nominal cover of concrete provide and maintain long lasting life of concrete, 2) it keep reinforcement free from corrosion and rust formation and prevent from damaging due to moisture condition in environment and in soil, 3) outer face of concrete …

What should be minimum cover for footing?

Minimum Nominal Cover Based on the Structure

  • For footing minimum nominal cover is – 15 mm minimum cover (as per is 456 the minimum nominal cover specified for footing is)
  • Flate Slab – 20 mm minimum cover.
  • Grade Slab – 20 mm minimum cover.
  • Beam – 25 mm minimum cover.
  • Strap Beam – 50 mm minimum cover.

What is cover and clear cover?

1) Nominal cover (concrete cover or clear cover) can be defined as “is the design depth of concrete cover to all steel reinforcements, including links”. This is the same thing as clear cover albeit with a different name.

READ ALSO:   Is majoring in computer engineering worth it?

How do you calculate the size of a column?

The column size for the building is calculated as per load coming on the column from the superstructure….Difference column sizes used in building design,

  1. 9″ x 9″
  2. 9″ x 12″
  3. 12″ x 12″
  4. 12″ x 15″
  5. 15″ x 18″
  6. 18″ x 18″
  7. 20″ x 24″
  8. As per Structural load more size can be used.

What is the diameter of reinforcement bar in a 400mm column?

For main reinforcement, up to 12 mm diameter bar for mild exposure the nominal cover may be reduced by 5 mm. A reinforced concrete column of size 400 mm × 400 mm is having the diameter of longitudinal bar as 20 mm. The pitch of lateral ties in such a case should be:

What is nominal cover and maximum diameter of the bar?

Maximum diameter of the bar. Nominal cover is the depth of concrete cover to all steel reinforcement including links, shear stirrups or column ties. It is the dimension used in design and indicated in the drawings. It shall not be less than the diameter of the bar in any case.

READ ALSO:   Are most software developers introverts?

What if the size of the column is less than required?

If the size of the column provided is less than that provided above, then the minimum eccentricity criteria are not satisfied. Then emin is more and the column is to be designed as uni axial bending case or bi axial bending case as the case may be.

What is the nominal cover of a longitudinal reinforcement bar?

(i)For a longitudinal reinforcement bar in a column, the nominal cover shall not be less than 40 mm or diameter of such bar. But in case of columns of minimum dimensions of 200 mm or under whose reinforcement bars do not exceed 12 mm, a nominal cover of 25 mm may be used.